CO₂ & Inert-Gas Flooding Systems

  • Home
  • CO₂ & Inert-Gas Flooding Systems

At Securix Multiple Solution, we deliver a clean-agent, total flooding system that quickly displaces oxygen or heat from the fire zone using carbon dioxide (CO₂) or inert gases like Argonite and FM-200. These systems are compliant with IS 6382, NFPA 2001, and IS 15493 for gas suppression systems.

1. CO₂ Flooding System

  • High-pressure or low-pressure cylinders with automatic release
  • Ideal for unmanned rooms and industrial enclosures
  • Removes oxygen to extinguish Class B and C fires
  • System includes delay timers and audible pre-discharge alarms
  • Manual abort switches and safety interlocks as per IS 6382

2. Inert Gas & Clean-Agent System

  • FM-200, Argonite, or Novec 1230 clean agents
  • Safe for occupied areas—leaves no residue
  • Rapid discharge (within 10 seconds) and even room flooding
  • Pressure-relief vents and post-discharge gas evacuation
  • No damage to electronics or documents

Key Features

  • Zero Water Damage: Ideal for areas with sensitive equipment
  • Fast Flooding: Suppression within seconds of detection
  • Safe for Personnel: Inert gas systems are non-toxic in design doses
  • Total Room Protection: Uniform distribution with automated room sealing
  • Remote Monitoring: Integration with BMS and fire panels for alerts & diagnostics

Why It Matters

  • Protects What Water Can’t: Server rooms, electrical panels, archives
  • No Clean-Up Required: Immediate restoration possible post-discharge
  • Compliant & Safe: Meets national and international fire safety standards
  • Ideal for Mission-Critical Zones: Downtime prevention in high-value setups

Installation Process

  • Site Survey & Hazard Mapping
  • Zone & Sensor Layout via CAD
  • Installation & Cabling
  • Panel Configuration & Testing
  • Training + System Handover

Ideal Applications

Data Centers, Control Rooms, Server Rooms, Archives, Electrical Panels, Laboratories, Industrial Cabinets, Telecom Hubs.

Ready to Secure Your Property?

Call For Consultation

Compliance Standards

  • IS 2189:2015 – Indian Standard for Fire Detection and Alarm Systems
  • NBC 2016 (Part 4) – National Building Code Fire Safety Norms
  • NFPA 72 – US National Fire Alarm and Signaling Code
  • IS 8884 – Maintenance and inspection recommendations

Suppress Fire Without Damage. Zero Residue. Zero Delay.

Our CO₂ and Inert-Gas Flooding Systems are designed for sensitive environments where traditional suppression methods like water or foam are unsuitable.